How to fix Dolphin CT50 Handheld scanner to use the Scanner and not the Camera

If you have purchased or already have a CT50 Handheld scanner, you may find the following steps help to get the Finale Application to use the Scanner and not the camera.


Under Settings > Scanning > Internal Scanner > Default Profile > Data Processing Settings

Wedge Checked

Wedge Method Keyboard

Charset = What your barcode system is

Prefix = Blank

Suffix = /x0D

(This suffix sends an ENTER command after scanning)

Wedge as key = Blank

Symbology Prefix = None for us


If Wedge as Keys is not an option:

Go to https://hsmftp.honeywell.com/

Note: Please ensure the Honeywell Download manager tool is installed on your PC prior to trying to download files. This tool is required for downloading files. The Download Manager installation file can be downloaded by clicking here

  1. Go to Software > Computer Devices > Handheld > Dolphin CT50 > Android 6

  2. Go to CommonES and Download

  3. Go to GMS > and Download the file starting in CT50-M-

Follow the steps in this video to place the files in the correct locations on the IPSM or SD Card (I used a 32gb MicroSD card), reboot in recovery mode, and install the files:

https://www.youtube.com/watch?v=3Bs61_gmj4Y&ab_channel=HoneywellHelp%26Support